 6 0 W U l t r a m i n i a t ure Medical Open Frame Switching Power Supplies
Up to 60W Output Power
ASM60
series
Universal 90-264VAC Input Single and Dual Outputs from 5VDC to 48VDC High Efficiency up to 86% 4000V Isolation 1U Compatible Height
2"W x 4"L x 1.2"H
Model Number
SINGLE OUTPUT ASM60-5(A)* ASM60-9(A)* ASM60-12(A)* ASM60-15(A)* ASM60-24(A)* ASM60-36(A)* ASM60-48(A)* DUAL OUTPUT ASM60D-1 ASM60D-2 ASM60D-3 ASM60D-5
Output Voltage Max. O/P Amps
Min. O/P Amps
Efficiency @ 230VAC R&N P-P Current Limit
5VDC 9VDC 12VDC 15VDC 24VDC 36VDC 48VDC (V1/V2) 5/12VDC 5/15VDC 5/24VDC 5/48VDC
9 6.66 5 4 2.5 1.66 1.25 (I1/I2) 5/3 5/2.4 5/1.5 5/0.73
0 0 0 0 0 0 0 1/0.60 1/0.48 1/0.30 1/0.15
73% 82% 84% 84% 86% 85% 86% 81% 82% 82% 82%
100mV 100mV 150mV 150mV 150mV 100mV 400mV 100/120mV 100/150mV 100/240mV 100/400mV
112% 135% 162% 162% 162% 125% 162% 150% 150% 150% 150%
*Note: The Single Outputs can be ordered with Molex 09-50-30x1 I/O connectors.. Simply add the suffix "A" to the end of the Model Number. For example, ASM60-5A
Order On-Line!
WWW.ASTRODYNE.COM
astrodyne.com
300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181
6 0 W U l t r a m i n i a t ure Medical Open Frame Switching Power Supplies
INPUT SPECIFICATIONS
Input Voltage Range Frequency Range Inrush Current, typ: Leakage Current 90-264 VAC 47-63 Hz 30A @ 100VAC Input * 60A @ 200VAC Input * <0.1mA
ASM60
4000VAC See Selection Chart 65Khz, (fixed, typical) UL, TUV, CB
series
GENERAL SPECIFICATIONS
Input-Out Isolation Efficiency Switching Frequency Safety
PHYSICAL SPECIFICATIONS OUTPUT SPECIFICATIONS
Size Voltage and Current Load Regulation (0%-FL) Single O/P: Dual O/P (V1/V2): Line Regulation (LL-HL) Single O/P: Dual O/P (V1/V2): Cross Regulation (Dual Outputs) (100-20% L w. other O/P at 60%) Preset Accuracy DC Voltage Adjust (typ) Temperature Coefficient Ripple/Noise, 20Mhz BW Over Voltage Protection Current Limit, Self Recovering Short Circuit Protection Hold Up Time (115V / 60Hz) See Selection Chart 1% 3/5% max 1% max 1/2% max 3/5% max 1% 6% of FS (Primary) 0.05%/C See Selection Chart Clamp, 118-130% See Selection Chart * Continuous, self-recovering * 10 mS, min. Construction Weight 2" x 4" x 1.2" 50.8 x 101.6 x 30.48mm Open Frame 7oz (198g)
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature Storage Temperature Relative Humidity EMC MTBF -10 to +50C(FL) , See Derate -25 to +85C * 0 to + 95%, non-cond * EN 60601-1-2:2001 185,000 Hrs Mil Std 217, 25C
OUTPUT DERATING CURVE
100 80 60 40 20
-10
0
10
20
30
40
50
60
All specifications are typical at nominal input, full load, and 25C unless otherwise noted
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied.
Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications.
WWW.ASTRODYNE.COM
300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181
6 0 W U l t r a m i n i a t ure Medical Open Frame Switching Power Supplies
MECHANICAL DIMENSIONS WITH JST CONNECTORS - STANDARD
ASM60
series
4 .0 0 0 1 0 1 .6 0
Input Connector: JST B3P-VH Input Mating Connector: JST VHR-3N or Molex 51144 Series Output Connector: JST B4P-VH Output Mating Connector: JST VHR-4N or Molex 53520 & 53521 Series Use with JST # SVH-21T-P1.1 or Molex # 50539-8100 Crimp Terminals All 4 corner holes need to be bonded accordingly to the end product PE (Protective Earth) path.
4 X O 3 .1 7 ( O 0 .1 2 5 )
1.165 29.60
0 .1 5 0 3 .8 0
3 .7 0 1 94
L N
3 4 5 6 1 2
2.000 50.80
1.701 43.20
0.150 3.80
Pin #
1 2 3 4 5 6
Single Outputs
AC Line AC Neutral + Output GND GND + Output
Dual Outputs
AC Line AC Neutral + Output 2 GND GND + Output 1
WWW.ASTRODYNE.COM
300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181
6 0 W U l t r a m i n i a t ure Medical Open Frame Switching Power Supplies
ASM60
series
MECHANICAL DIMENSIONS WITH MOLEx CONNECTORS ("A" VERSIONS SINGLE OUTPUTS ONLY)
4 .0 0 0 1 0 1 .6 0
Input Connector: Molex 09-50-3031 Input Mating Connector: JST VHR-3N or Molex 51144 Series Output Connector: Molex 09-50-3041 Output Mating Connector: JST VHR-4N or Molex 53520 & 53521 Series Use with JST # SVH-21T-P1.1 or Molex # 50539-8100 Crimp Terminals All 4 corner holes need to be bonded accordingly to the end product PE (Protective Earth) path.
4 X O 3 .1 7 ( O 0 .1 2 5 )
1.165 29.60
0 .1 5 0 3 .8 0
3 .7 0 1 94
L1 N2
3 4 5 6
2.000 50.80
1.701 43.20
0.150 3.80
Pin #
1 2 3 4 5 6
Single Outputs
AC Line AC Neutral + Output + Output GND GND
WWW.ASTRODYNE.COM
300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181


▲Up To Search▲   

 
Price & Availability of ASM60-12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X